TC35i AT Command Set
15.10 AT^SNFD
s
m
obil
e
TC35i_ATC_V02.07 Page 377 of 439 1/30/04
Confidential / Released
15.10 AT^SNFD Set audio parameters to manufacturer default values
Syntax
Command Description
TA sets the active audio parameters to manufacturer defined default values.
Notes
The restored values are:
AT^SNFI: <inBbcGain>, <inCalibrate> (or the equivalent AT^SNFA parameters)
AT^SNFO: <outBbcGain>, <outCalibrate>[0 to 4], <sideTone>
AT^SAIC
: <io>, <mic>, <ep>
AT^SNFS
: <audMode>
Remember that the factory set audio mode 1 is fixed to
<outStep>=4. Consequently, AT^SNFD restores
<audMode> together with <outStep>=4, but does not affect the values of <outStep> currently selected in
audio modes 2 - 6. This means, if
<audMode>=1, the read commands AT^SNFO, AT^SNFV and AT+CLVL will
always return
<outStep>=4. In all other modes the <outStep> value is retained until explicitly changed.
Test Command
AT^SNFD=?
Response(s)
OK
Exec Command
AT^SNFD
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
SIEMENS