TC35i AT Command Set
4.3 AT&D
s
m
obil
e
TC35i_ATC_V02.07 Page 88 of 439 1/30/04
Confidential / Released
4.3 AT&D Set circuit Data Terminal Ready (DTR) function mode
Syntax
Command Description
This parameter determines how the TA responds when circuit 108/2 (DTR) is changed from ON to OFF during
data mode.
Parameter Description
[0] TA ignores status of DTR.
1 ON->OFF on DTR: Change to command mode while retaining the connected
call.
2
(&F)
ON->OFF on DTR: Disconnect data call, change to command mode. During
state DTR = OFF is auto-answer off.
Exec Command
AT&D[<value>]
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter
<value>
(num)(&W)(&V)