TC35i AT Command Set
2.14 AT^SCFG
s
m
obil
e
TC35i_ATC_V02.07 Page 53 of 439 1/30/04
Confidential / Released
2.14 AT^SCFG Extended Configuration Settings
This command can be used to query and configure various settings of the TC35i.
Syntax
Unsolicited Result Code
^SCFG: "AutoExec", <AutoExecState>, <AutoExecType>, <AutoExecIndex>,
<AutoExecMode>, <AutoExecATC>
If the event specified with <AutoExecType> occurs and the related AT command line is executed this URC is
issued.
Test Command
AT^SCFG=?
Response(s)
^SCFG: "AutoExec" , (list of supported <AutoExecCmd>), (list of supported <AutoExecType>), (list of
supported
<AutoExecIndex>), (list of supported <AutoExecMode>), (max. string length of
<AutoExecATC>), (time range of <AutoExecPeriod>)
OK
Read Command
AT^SCFG?
Response(s)
^SCFG: "AutoExec" , <AutoExecCmd>, <AutoExecType>, <AutoExecIndex>, <AutoExecMode>,
<AutoExecATC>[, <AutoExecPeriod>]
OK
Write Command
Automatic AT command execution
AT^SCFG="AutoExec" , <AutoExecCmd>, <AutoExecType>, <AutoExecIndex>[, <AutoExecMode>,
<AutoExecATC>[, <AutoExecPeriod>]]
Response(s)
^SCFG: "AutoExec" , <AutoExecCmd>, <AutoExecType>, <AutoExecIndex>, <AutoExecMode>,
<AutoExecATC>[, <AutoExecPeriod>]
OK
ERROR
+CME ERROR
PIN ASC0 MUX1 MUX2 MUX3
! % § § §
Reference(s)
SIEMENS

Table of Contents