TC35i AT Command Set
7.28 AT^STCD
s
m
obil
e
TC35i_ATC_V02.07 Page 183 of 439 1/30/04
Confidential / Released
7.28 AT^STCD Display Total Call Duration
Syntax
Command Description
TA returns total call duration (accumulated duration of all calls).
Parameter Description
Format is "hh:mm:ss", where characters indicate hours, minutes, seconds; E.g. 22:10:00 "22:10:00"
Max value is 9999:59:59
Note
The Total Call Duration will not be reset by power off or other means.
Test Command
AT^STCD=?
Response(s)
OK
Exec Command
AT^STCD
Response(s)
^STCD: <time>
OK
PIN ASC0 MUX1 MUX2 MUX3
% % % % %