TXP-CLC Course
Some times it is necessary to make a connection between two modules within the same diagram. For this we
will create a connector on the origin page, and another connector will be created on the target page with the
same name. Follow the procedure below to accomplish this:
1
1
.
Click on the desired signal
(handle points
appear)
2.
Hold the middle mouse button and select
create connection” from the mask, then
release the middle mouse button
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
2
positive signal
negative signal
action line
flow line
3.
Drag the mouse to the desired end point of the
connector and then press the middle mouse button.
Release the middle mouse button on “positive signal”
A
V will appear at the end of the line indicating that
the connection is open
3
4
4.
(handle points
appear)
5.
Hold down the middle mouse button and select
parameter” then “edit connector” from the
masks. Release the middle mouse button
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
5
Edit ZULI
Rename signal
Rename identifier
Change signal
Edit connector
Signal-Verw.
6.
Type the connector name
7.
Go to the target page of
the diagram.
FUP menu:
Page -> Goto page
6
8
Paste
Refresh
Create connection
Go up
Create connection
8.
From the desired beginning point of the new line press
and hold the middle mouse button. Select “create
connection” from the mask.
9.
Drag the mouse into the desired
module’s input and close
connection as shown
9
positive signal
negative signal
action line
flow line
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
Properties
Parameter
Align
Cut
Deselect
Create connection
Modify connection
Disconnect
Follow signal
Simulation
10
Edit ZULI
Rename signal
Rename identifier
Change signal
Edit connector
Signal-Verw.
11
10.
Left click in the open connection
11.
12.
Type in the exact connector name as the origin connector,
then press "OK"
12
13.
With nothing selected on the diagram press and hold the middle
mouse button, then select “refresh” from the mask.
If everything is okay the page number should appear below the
connector name. Otherwise, the name are not exactly matched
(
connectors are u
pp
er and lower case sensitive
)
Paste
Refresh
Create connection
Go up
Refresh
13
Left click on the open connection
Hold the middle mouse button down
and select “parameter” then “edit
connector” from the masks