Simrad AP26 and AP27 Autopilots
86 20222147A
Counter Rudder
is the parameter that counteracts the effect of
the boats turn rate and inertia. For a short time period it is
superimposed on the proportional rudder response as provided
by the heading error. It may sometimes appear as if it tends to
make the rudder move to the wrong side (counter rudder).
The best way of checking the value of the Counter Rudder
setting is when making turns. The figures illustrate the effects off
various Counter Rudder settings.
Autotrim
standard value is 40 sec. which should work well on
most boats.
Recall Autotuned?
To recall the parameter values
that were achieved during the
Automatic tuning procedure,
rotate the course knob
clockwise. When parameter
values are recalled, Confirmed
is displayed.
N
ew course
Counter rudder setting too
low, overshoot response
Correct setting of counter
rudder, ideal response
N
ew course
Counter rudder setting too high,
sluggish and creeping response
ew course

Table of Contents

Other manuals for Simrad AP26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad AP26 and is the answer not in the manual?

Simrad AP26 Specifications

General IconGeneral
BrandSimrad
ModelAP26
CategoryAutopilot System
LanguageEnglish

Related product manuals