12 Troubleshooting
SMA Solar Technology AG
Operating manual EVC22-3AC-20-BE-en-10 91
Explanation:
The charging mode was changed to the displayed mode.
12.1.22 Event 9805
Event message:
Charging mode was interrupted by vehicle.
Explanation:
The vehicle has interrupted the charging process.
Corrective measures:
Opening and closing of the vehicle by radio remote control.
Remove the charging cable from the vehicle and then reconnect the charging cable to the
vehicle.
Check and if necessary adjust the settings in the vehicle's user interface.
12.1.23 Event 9806
Event message:
A proximity pilot fault has occurred in the charging cable, the charging cable does not meet
any specification, or is defective.
Corrective measures:
Use appropriate charging cable.
12.1.24 Event 9807
Event message:
The charging port cannot be locked.
Corrective measures:
Check the plug connections and plug in the cable until it stops. If the event persists, contact
Service and have the parameters and diagnostic data ready.
12.1.25 Event 9808
Event message:
The charging port cannot be unlocked.