Command Line Interface
4-46
4
logging trap
This command enables the logging of system messages to a remote server, or
limits the syslog messages saved to a remote server based on severity. Use this
command without a specified level to enable remote logging. Use the no form to
disable remote logging.
Syntax
logging trap [level]
no logging trap
level - One of the level arguments listed below. Messages sent include the
selected level up through level 0. (Refer to the table on page 4-44.)
Default Setting
Enabled
Level 6 - 0
Command Mode
Global Configuration
Command Usage
Using this command with a specified level enables remote logging and sets
the minimum severity level to be saved.
Using this command without a specified level also enables remote logging, but
restores the minimum severity level to the default.
Example
clear logging
This command clears messages from the log buffer.
Syntax
clear logging [flash | ram]
flash - Event history stored in flash memory (i.e., permanent memory).
ram - Event history stored in temporary RAM (i.e., memory flushed on
power reset).
Default Setting
Flash and RAM
Command Mode
Privileged Exec
Example
Console(config)#logging trap 4
Console(config)#
Console#clear logging
Console#