Command Line Interface
4-104
4
Command Mode
Global Configuration
Example
Related Commands
snmp-server contact (4-103)
snmp-server host
This command specifies the recipient of a Simple Network Management Protocol
notification operation. Use the no form to remove the specified host.
Syntax
snmp-server host host-addr [inform [retry retries | timeout seconds]]
community-string [version {1 | 2c | 3 {auth | noauth | priv} [udp-port port]}
no snmp-server host host-addr
host-addr - Internet address of the host (the targeted recipient).
(Maximum host addresses: 5 trap destination IP address entries)
inform - Notifications are sent as inform messages. Note that this option is
only available for version 2c and 3 hosts. (Default: traps are used)
- retries - The maximum number of times to resend an inform message if
the recipient does not acknowledge receipt. (Range: 0-255; Default: 3)
- seconds - The number of seconds to wait for an acknowledgment before
resending an inform message. (Range: 0-2147483647 centiseconds;
Default: 1500 centiseconds)
community-string - Password-like community string sent with the
notification operation to SNMP V1 and V2c hosts. Although you can set this
string using the snmp-server host command by itself, we recommend that
you define this string using the snmp-server community command prior
to using the snmp-server host command. (Maximum length:
32 characters)
version - Specifies whether to send notifications as SNMP Version 1, 2c or
3 traps. (Range: 1, 2c, 3; Default: 1)
- auth | noauth | priv - This group uses SNMPv3 with authentication, no
authentication, or with authentication and privacy. See “Simple Network
Management Protocol” on page 5-1 for further information about these
authentication and encryption options.
port - Host UDP port to use. (Range: 1-65535; Default: 162)
Default Setting
Host Address: None
Notification Type: Traps
Console(config)#snmp-server location WC-19
Console(config)#

Table of Contents

Other manuals for SMC Networks SMC8126L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks SMC8126L2 and is the answer not in the manual?

SMC Networks SMC8126L2 Specifications

General IconGeneral
BrandSMC Networks
ModelSMC8126L2
CategorySwitch
LanguageEnglish

Related product manuals