Page #55 background imageLoading...
Page #55 background image
+9<47043,/-:7'9/43
 389'11'9/43'3:'1 +)9/43389'11'9/43? '-+
#"&" %"$ $#
The default network settings for the console server, such as its hostname and the IP address allocation method, can be
changed to suit the client’s IT infrastructure.
It is important that values for the network settings are provided by whoever administers the facility’s IT systems.
A range of system settings are configurable via a system setup menu as shown below.
To access the server’s set-up menu:
Log in to the console server as ‘root’ using the appropriate method shown previously.
At the server prompt type: ‘ssl_setup’ <CR>
The set-up program offers a list of options available to the user. Each option provides on-screen prompts.
Refer to page 4-17 for further information relating to the use of SNMP.
## #"&" #$  $ 
It is recommended that the SBC server is given a hostname; particularly if using DHCP as the IP assignment method. This
name can then be used to identify the server for future logins (In the examples shown on the previous pages it will be noticed
that the server has already been named as ’electra’).
NOTE. In order for the change of name to become effective it will be necessary to reboot the Linux core of the SBC computer.
DO NOT assign a new hostname if the console is in use as network changes can result in a temporary loss of control.
To assign a hostname and to reboot the core:
Enter the chosen hostname string using the ssl_setup program as shown above.
Save and exit the setup program using the ‘(s)’ option. (You may receive a network restart message).
Then, at the server prompt, type: ‘reboot’ <CR>
The core will then immediately restart and you will be logged out.
i

Table of Contents

Other manuals for Solid State Logic C100 HDS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solid State Logic C100 HDS and is the answer not in the manual?

Solid State Logic C100 HDS Specifications

Power IconPower
console power100-240 V AC
power consumption300-700 W
DSP and Audio Processing IconDSP and Audio Processing
maximum input channels256
second input path channels512
utility busses24 mono
aux busses24 mono
dedicated ASG buses16
dedicated PGM buses12
delay modules64 modules, 5.4 seconds each
Weight and Dimensions IconWeight and Dimensions
max height100.6 cm
weight (40 fader)190 kg
height adjustment0 to +1 cm
width (40 fader, flat end trim)143.1 cm
max depth92.6 cm