294
Macro File Editing Rules
Appendix
TransitionType ME? ME1, PP Control blocks on the applicable bank
TransitionType? Mix, NAM, SuperMix,
PresetColorMix, Wipe,
DMEWipe,
FM1&2Clip, FM3&4Clip,
FM5&6Clip, FM7&8Clip
Transition type
KeyTransitionType ME? ME1, PP Control blocks on the applicable bank
Key? Key1 to Key4 Key of the applicable independent key transition
Direction? On (a),
Off (b)
Any (c)
Independent key transition execution mode
(a): Key is inserted
(b): Key is deleted
(c): Transition is always executed
KeyTransitionType? Mix, Wipe, DMEWipe, Cut Transition type of the independent key transition
NextTransition ME? ME1, PP Control blocks on the applicable bank
All? On, Off Applicable next transition
KeyPriority? On, Off Applicable next transition
BKGD? On, Off Applicable next transition
Key1 to Key8 On, Off Applicable next transition
FadeToBlack Time? Current (a),
0 to 999
Transition rate (number of frames)
(a): Mode in which the current value set in fade
to black is used
TimelineDirectionNormal
Region? ME1, PP,
User1 to User8,
PBus, Device1 to Device12,
GPI, Current (a)
Applicable region
(a): Mode in which operation takes place in the
region currently specified in the Flexi Pad
TimelineDirectionReverse
Region? ME1, PP,
User1 to User8,
PBus, Device1 to Device12,
GPI, Current (a)
Applicable region
(a): Mode in which operation takes place in the
region currently specified in the Flexi Pad
TimelineNormalReverseOn
Region? ME1, PP,
User1 to User8,
PBus, Device1 to Device12,
GPI, Current (a)
Applicable region
(a): Mode in which operation takes place in the
region currently specified in the Flexi Pad
TimelineNormalReverseOff
Region? ME1, PP,
User1 to User8,
PBus, Device1 to Device12,
GPI, Current (a)
Applicable region
(a): Mode in which operation takes place in the
region currently specified in the Flexi Pad
UtilityButton UtilityModule? UserPrefs,
UtilityBox
Control blocks on the applicable bank
Button? 1 to 96 Applicable button
UtilityStatus? On,
Off,
Current (a)
Status of function assigned to button
(a): Operates according to currently assigned
function
FMLoop Device? FrameMemory1Clip to
FrameMemory8Clip
Applicable clip
FMLoopMode? On (a),
Off (b)
Frame memory clip loop on/off
(a): Loop is enabled
(b): Loop is disabled
MenuMacroRun Register? 1 to 99 Applicable register number
Symbol Parameter name Arguments Description