19
b Display
The display shows the following information.
• Settings of buttons on the 1st row to 4th row (signal
n
ame, bus name, register name, or function name
assigned to the button)
• Macro register name of macro attach
ment assigned to
the 1st row to 4th row buttons
When the [SHIFT] button function is set, “SHFT”
ap
pears on the display. When the shifted state is selected,
“SHFT” is displayed highlighted, and the button
information also toggles to show the shifted state display.
Display mode
Six types of display mode can be set according to the
in
formation to display. You can switch the mode using
the display mode button assigned to the cross-point pad.
The display can also be subdivided (top and bottom) to
display two pieces of information.
For details, see “Setting the Display” (page 404).
c Cross-
point indicators
When lit, these indicate the source
color of the video
signal assigned to buttons on the 3rd row.
If a signal cannot be selected, because a signal is not
assigne
d or the inhibit setting is set, the indicator is not lit.
You can disable the cross-point in
dicators so that they do
not turn on.
For details, see “Setting the on/off state of cross-point
indicators” (page 404).
d Cross-point
pad (assignable buttons)
You can assign functions, such as settings and operations,
of t
he cross-point button rows in the Home > Setup >
Panel > Xpt Module > Xpt Pad Button Assign menu
(19104.36).
You can configure up to 14 pages (page 1 to page 14) of
sett
ings, where each page contains functions assigned to
the 15 cross-point pad buttons as a group.
For details about assigning buttons, see “Setting a Cross-
Point Pad” (page 405).
Cross-point pad operation
Select a cross-point pad page (page 1 to page 14) to
switc
h the functions assigned to the buttons.
Page selection is done using the following buttons.
• [HOME] button: Display the home page.
• [<<] button: Move to the previous page.
• [>>] button: Move to the next page.
• Button assigned with page recall function: Display the
speci
fied page.
You can also press the current page name display button
o
r simultaneously press the [<<] button and [>>] button to
switch from the cross-point pad to the select page display
and then press a button to select a page to display. To exit
the select page display, press the [EXIT] button.
The button assigned with the page recall function has a
wh
ite frame added to the button name display.
Assignable functions
4th row • Selects the background B bus signal when
in key/AUX bus delegation mode or key bus
mode.
• Selects the bus signal assigned by the
d
elegation buttons in the cross-point pad
when in free assign mode.
Selects the utility function wh
en a utility/
shotbox bank is assigned using the
delegation buttons in the cross-point pad.
• Selects the utility 2 bus signal when in utility
bus mode.
Name Description
Note
Function name Button
name
Description
Others:
Home
HOME Displays the home page
o
f the cross-point pad.
Others:
Prev
<< XXX Displays the previous
page of the cross-point
pad.
XXX = Page name (up
to 12
characters)
Others:
Next
>> XXX Displays the next page
of the cross-point pad.
XXX = Page name (up
to 12 characters)
Others:
Current Page
St
atus
PAGE1
XXX to
PAGE14
XXX
Displays the number
a
nd name of the
currently displayed
page.
XXX = Page name (up
to 12 characters)
Current page
name display
button
HOME button