290
Changing main/sub configuration data in
multi program 2 mode
When a snapshot is recalled on main or sub in multi
program 2 mode, only the keys being used on main and
sub, according to the operation mode configuration data
of the switcher bank, become the recall target.
You can also automatically change the operation mode
con
figuration data saved in a register when copy/move/
swap operations are performed between main and sub
registers.
You can enable/disable this using the [MP2 Auto Config]
bu
tton when main and sub on a switcher bank are selected
as the target regions in the Home > Register > Snapshot >
Edit Register > Copy/Move/Swap menu (18302.13).
On: Ch
ange the operation mode configuration data for
main and sub.
Off: Do
not change the operation mode configuration
data.
The setting of the [MP2 Auto
Correct] button is common
to effect timelines.
Locking a register
1
Open the snapshot register display menu.
To lock a multi region register
Open the Home > Register > Snapshot > Edit
Reg
ister > Browse Multi Rgn menu (18302.11).
To lock a single region register
Open the Home > Register > Snapshot > Edit
Reg
ister > Browse Single Rgn menu (18302.12).
2
Select the target region to set.
For details about selecting multiple regions, see “To
select a region” (page 287).
For details about selecting a single region, see “To
select a region” (page 288).
3
In the list on the left, select the target register to lock.
To select and lock multiple re
gisters, place a check
mark beside the target registers to lock.
To select and lock all registers, pl
ace a check mark in
the Select All checkbox.
You can also press the [Select Register(s)] button and
e
nter a register number in the numeric keypad
window.
4
Press the [Lock] button.
To release the lock
Select the target register to un
lock and press the [Unlock]
button.
Deleting a register
A locked register cannot be deleted.
1
Open the snapshot register display menu.
To delete a multi region register
Open the Home > Register > Snapshot > Edit
Register
> Browse Multi Rgn menu (18302.11).
To delete a single region register
Open the Home > Register > Snapshot > Edit
Register
> Browse Single Rgn menu (18302.12).
2
Select the target region to set.
For details about selecting mul
tiple regions, see “To
select a region” (page 287).
For details about selecting a single region, see “To
select a region” (page 288).
3
In the list on the left, select the target register to
delete.
To select and delete multiple registers, place a check
m
ark beside the target registers to delete.
To select and delete all registers, place a check mark
in
the Select All checkbox.
You can also press the [Select Register(s)] button and
ent
er a register number in the numeric keypad
window.
4
Press the [Delete] button.
5
Check the message, then press [OK].
Renaming a register
A locked register cannot be renamed.
1
Open the snapshot register display menu.
To rename a multi region register
Open the Home > Register > Snapshot > Edit
Register
> Browse Multi Rgn menu (18302.11).
To rename a single region register
Open the Home > Register > Snapshot > Edit
Register
> Browse Single Rgn menu (18302.12).
2
Select the target region to set.
For details about selecting mul
tiple regions, see “To
select a region” (page 287).
Note
Note
Note