• In multi program 2 mode, main and sub can be set
separately. When a switcher bank is set to shared
main and sub, the button assignments are also
shared.
3
Display the target page to set.
Select a tab to change the page (Page 1 to Page 14) to
display.
4
Press the target button to set in [Button Assign].
The [Select Function] wi
ndow appears.
The functions that can be assigned to the cross-point
pad butt
on are displayed in the [Select Function]
window.
Select a tab to change the function to display.
When a switcher bank is sel
ected in the [Select
Bank] group
[Row-1 Bus] tab to [Row-4 Bus] tab: Swit
cher bank
buses to assign to the 1st row to 4th row
[Row-1 Aux] tab to [Row-4 Aux] tab: AU
X buses
to assign to the 1st row to 4th row
[Row-1 Func] tab to [Row-4 Func] tab: Functions
to assi
gn to the 1st row to 4th row
[Others] tab: Othe
r functions
[Table/Macro] tab:
Cross-point assign tables and
macro registers
When an AUX bus control block is selected in the
[Select Bank
] group
[Row-3/4 Func] tab: Functi
ons to assign to the 3rd
row/4th row
[Others] tab: Othe
r functions
[Macro] tab: Macr
o registers
5
Set the button for the function to assign to the on
state.
[Table/Macro] tab or [Macro] t
ab, table selection
buttons/register selection buttons
Set the radio button to the on
state, press the input
field, and enter the table number/register number in
the numeric keypad window.
To release the assignment
Set the [No Assign] button to the on state.
6
Press [OK].
To set a page name
Press the [Page Name] button and enter a page name (up
to 1
2 characters) using the keyboard.
To set the page recall function
You can set to display a particular page wh
en a cross-
point pad button is pressed.
Buttons configured with a page recall function have a
whi
te frame around the cross-point pad buttons in the
control panel.
The page recall function can be a
ssigned to buttons in the
cross-point pad to which already have another function
assigned.
1
Press the target button to set in [Jump Page Assign].
The [Select Page] window appears.
2
Set the button for the page to recall to the on state.
To release the page recall function setting
Set the [No Assign] button to the on
state.
3
Press [OK].
To release all button assignments
Press the [All Clear] button.
The functions assigned to the butt
ons on the selected page
and the page recall function settings are deleted.
About re-entry signal selection buttons
By default, the following signals are assigned to
cross-
point button numbers 285 to 300.
The re-entry signal selection but
tons in the cross-point
pad use signals assigned to button numbers 285 to 290
and button numbers 293 to 298.
Note
Function name
a)
Cross-
point
button
number
V/K pair
number
Signal
Row-n Xpt Btn
No.285
285 81 M/E-1 Out1
Row-n Xpt Btn
No.28
6
286 89 M/E-2 Out1
Row-n Xpt Btn
No.287
287 97 M/E-3 Out1
Row-n Xpt Btn
No.288
288 73 P/P Out1
Row-n Xpt Btn
No.28
9
289 105 M/E-4 Out1
Row-n Xpt Btn
No.290
290 113 M/E-5 Out1
Row-n Xpt Btn
No.291
291 291 (black signal)
Row-n Xpt Btn
No.29
2
292 292 (black signal)
Row-n Xpt Btn
No.293
293 85 M/E-1 Out5
Row-n Xpt Btn
No.294
294 93 M/E-2 Out5
Row-n Xpt Btn
No.29
5
295 101 M/E-3 Out5