414
2
In the [Main Split Fader] group, select the main fader
lever.
Left: Set the left fader lever as the main fader lever.
Right: Set the right fader lever as the main
fader
lever.
Setting the Mode of Buttons in the
Cross-Point Control Block
Setting the operation mode of the [UTIL]
button in the cross-point control block
1
Open the Home > Setup > Panel > Custom >
Operation Mode menu (19104.61).
2
In the [Util Button] group, select an operation mode.
Hold: Ena
bles utility bus mode only while the
[UTIL] button is pressed.
Lock: Pressing t
he [UTIL] button switches between
utility bus mode and normal mode each time the
button is pressed.
Setting the operation mode of the [KEY]
button in the cross-point control block
You can set the signal to select on the key source bus.
1
Open the Home > Setup > Panel > Custom >
Operation Mode menu (19104.61).
2
In the [Key Source Bus Select Mode] group, select an
operation mode.
Key: The [KEY
] button is always lit and only key
signals can be selected.
Video & Key: Enables
key signals or video signals to
be selected using the [KEY] button operation.
Setting the Mode of Buttons in the
Flexi Pad Control Block
Setting the button display in wipe
snapshot operation mode/DME wipe
snapshot operation mode
You can set the memory recall button display in wipe
snapshot operation mode/DME wipe snapshot operation
mode.
1
Open the Home > Setup > Panel > Custom > Flexi
Pad Mode menu (19104.62).
2
In the [Wipe/DME Display] group, select a button
display.
Pattern: Di
splay pattern image.
Register Name: Di
splay register name.
Setting the button display in snapshot
operation mode
You can set the memory recall button display in snapshot
operation mode.
1
Open the Home > Setup > Panel > Custom > Flexi
Pad Mode menu (19104.62).
2
In the [Snapshot Display] group, select a button
display.
Register No.: Display register number.
Register Name: Di
splay register name.
Assigning a register to bottom left button
of bank 0
You can assign a register to the bottom left memory recall
button when bank 0 is selected in snapshot operation
mode/shotbox operation mode/macro operation mode.
1
Open the Home > Setup > Panel > Custom > Flexi
Pad Mode menu (19104.62).
2
Set the [Activate] button in the [Bank 0 Register
Assign] group to the on state.
3
Press the [Register No.] button in the [Bank 0
Register Assign] group and enter a register number in
the numeric keypad window.
To release the register assignment
Set the [Activate] bu
tton in the [Bank 0 Register Assign]
group to the off state.
Switching the operation mode in sync
with the transition control block
You can switch the operation mode of the Flexi Pad
control block in sync with the selection of the [WIPE]
button or [DME] button in the transition control block/
transition control block (simple type).
1
Open the Home > Setup > Panel > Custom > Flexi
Pad Mode menu (19104.62).
2
Set the [Wipe/DME Auto Deleg] button to the on
state.
To release the link
Set the [Wipe/DME Auto Deleg] bu
tton to the off state.