EasyManua.ls Logo

ST STM32F31xx - Page 296

ST STM32F31xx
584 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operational amplifier (OPAMP)
UM1581
296/584
DocID023800 Rev 1
OPAMP :
Return values
Returns the selected OPAMP output level: low or high.
Notes
OPAMP ouput level is provided only during calibration phase.
16.2.4.12 OPAMP_OffsetTrimModeSelect
Function Name
void OPAMP_OffsetTrimModeSelect ( uint32_t
OPAMP_Selection, uint32_t OPAMP_Trimming)
Function Description
Select the trimming mode.
Parameters
OffsetTrimming : the selected offset trimming mode. This
parameter can be one of the following values:
OPAMP_Trimming_Factory : factory trimming values
are used for offset calibration
OPAMP_Trimming_User : user trimming values are
used for offset calibration
Return values
None.
Notes
When OffsetTrimming_User is selected, use
OPAMP_OffsetTrimConfig() function or
OPAMP_OffsetTrimLowPowerConfig() function to adjust
trimming value.
16.2.4.13 OPAMP_OffsetTrimConfig
Function Name
void OPAMP_OffsetTrimConfig ( uint32_t OPAMP_Selection,
uint32_t OPAMP_Input, uint32_t OPAMP_TrimValue)
Function Description
Configure the trimming value of the OPAMP.
Parameters
OPAMP_Selection : the selected OPAMP. This parameter
can be OPAMP_Selection_OPAMPx where x can be 1 to 4 to
select the OPAMP peripheral.
OPAMP_Input : the selected OPAMP input. This parameter
can be one of the following values:
OPAMP_Input_Inverting : Inverting input is selected to
configure the trimming value
OPAMP_Input_NonInverting : Non inverting input is
selected to configure the trimming value
OPAMP_TrimValue : the trimming value. This parameter

Table of Contents