QA BEAMCHECKER™ PLUS 53
Take Advantage of the Synchronize Function
A synchronization operation can be useful if using the QA BeamChecker Plus with more than
one database. If using one QA BeamChecker Plus in any situation where more than the
allowed 9 treatment rooms are required, multiple databases can be created, each with their
own 9 treatment rooms. Additionally, one database could contain a test configuration, and
another could contain “official” measurement data. Simply perform measurements with one
database, download the data, and synchronize to another database to switch between
multiple files.
11 Using Other Accessories
11.1 Bluetooth Adapter Kit
The Bluetooth Adapter Kit (REF 70504) allows QA BeamChecker Plus wireless communication
for operations that typically require a cable connection to the PC such as baseline, Real-Time
Operation and Physics mode measurements.
Each kit includes two adapters, one with a male interface and with a female interface. Each
adapter must be supplied with a power source. The QA BeamChecker Plus internal battery
provides power through the serial port to the male interface adapter, so no external power
adapter is required. However, the female interface adapter connected to the PC or cradle
requires power via an included external adapter. See image for an illustration of a typical
configurations.
Using the Bluetooth Adapter Kit
1. If already using the QA BeamChecker Plus Data/Communication Cradle in the vault with a
cable attached from the PC, skip this step. If not, run a 9-pin serial cable from the PC into the
treatment vault.
2. If using the cradle as stated in step 1, connect the male Bluetooth interface adapter to the
Serial Pass Through port on the cradle. If not using the cradle, connect the male Bluetooth
interface adapter directly to a cable run from the PC.
NOTE: The Bluetooth Adapter Kit will not communicate through the treatment vault wall, but
because their signal is transmitted via RF, the cradle (with attached adapter) can be placed
inside a cabinet or closet and still communicate effectively.
3. Connect the included power adapter from the male Bluetooth interface adapter to an
available power outlet.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Standard Imaging QA BEAMCHECKER PLUS and is the answer not in the manual?

Standard Imaging QA BEAMCHECKER PLUS Specifications

General IconGeneral
BrandStandard Imaging
ModelQA BEAMCHECKER PLUS
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals