7.7.3 GROUNDING
Check condition of cables and connections and tight t of main grounding cable: Battery
to engine suspension frame and grounding cable on LH engine suspension shock mount.
Check condition of cables and connections and tight t of grounding cables on fuel pumps.
7.7.4 EBOXES
Check condition of electric distribution box assy. on rear fuselage steel frame.
Check tight t of connections, tight t of auxiliaries (capacitor, regulator) and fuses.
Open E-boxes and check cables, connections and components for damage, fastening,
foreign objects and moisture.