8 | Commissioning STÖBER
66
11/2017 | ID 442793.00
8.2.2.3 Limiting the axis
If necessary, limit the movement variables for position, velocity, acceleration, jerk as well as
torque/force according to the applicable conditions for your drive model.
Limiting the position (optional)
1. Highlight the relevant drive controller in the project tree and click on the first projected axis
in the project menu > Wizard section.
2. Select the Axis model > Limit position wizard.
3. If necessary, limit the position of your axis using a software or hardware limit switch to
secure the travel range.
Limiting velocity, acceleration, jerk (optional)
The specified default values are designed for slow velocities without gear units. For this reason,
adapt the saved values.
Note that the velocity of the motor is parameterized in units other than that of the axis model.
Verify the velocity of the motor against the velocity of the output accordingly.
1. Select the Motor wizard.
2. To determine the maximum velocity at the output, copy the value of the B13 Nominal motor
speed parameter to the clipboard.
3. Select the Axis model > Scaling axis wizard > Conversion of positions, velocities,
accelerations, torque/force section.
4. Velocity line:
Paste the copied value of the B13 parameter from the clipboard and confirm with ENTER.
ð The maximum velocity of the motor has been transferred to the output.
5. Select the Axis model > Limit velocity, acceleration, jerk wizard.
6. I10 Maximal speed:
Limit the maximum velocity of the output taking into account the configured Nominal motor
speed in B13.
7. Determine the limiting values for acceleration and jerk if necessary and enter them into the
associated parameters.
Limiting torque/force (optional)
The specified default values take into account the rated operation together with the overload
reserves.
1. Select the Axis model > Limit torque/force wizard.
2. If the motor force must be limited, adapt the saved values as necessary.

Table of Contents

Other manuals for Stober SC6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stober SC6 Series and is the answer not in the manual?

Stober SC6 Series Specifications

General IconGeneral
BrandStober
ModelSC6 Series
CategoryController
LanguageEnglish

Related product manuals