When you first receive your Firewall, it will run in transparent (bridge) mode and will have the IP
address 10.0.0.254 with a subnetwork mask 255.0.0.0. These parameters might not match your
network configuration, but they are however necessary for the pre-configuration phase.
To connect to the Firewall, you will need to use a workstation on which DHCP has been enabled,
or its IP address has to be in the same address range as your Firewall (10.0.0.0/8). DHCP is
enabled by default on Windows platforms If this is not the case, refer to the section Network
configuration of your client workstation. If you do not know what these parameters mean, we
strongly advise you to read up on TCP/IP as it would be very difficult for you to configure your
Stormshield Network Firewall without at least this knowledge.
NOTE
For a manual configuration, we suggest that you use the IP address 10.0.0.1 and the
subnet mask 255.0.0.0.
Network configuration of your client workstation
If DHCP has not been enabled on your client workstation, or for manual configurations, modify the
Network connection parameters of your operating system.
In Windows, you generally need to select Internet Protocol (TCP/IP) from the list, then
Properties”, and select the option Obtain an IP address automatically.
To manually configure this network, enter the necessary address information. During the initial
connection, the IP address of this workstation will need to belong to the same address range as
the Firewall, 10.0.0.0/8 by default.
Starting
WARNING
You must not unplug the product when it is starting, shutting down or being upgraded.
Except for SN910 appliances, these phases are indicated when the following LEDs are lit:
l Power 3 and Status 2 LEDs for SN160, SN160W, SN210, SN210W, SN310, SN510,
SN710, SN2100 and SN3100 models
l Power 3 LEDs for SN6100 and SNi40 models.
For SN160, SN160W, SN210, SN210W, SN310, SN510, SN710, SN2100 and SN3100 models,
upon startup, the LEDs light up in the following order:
Power 3 + Status 2 => Online 1
The Power and Status LEDs will light up first.
After a few minutes, the Online LED will light up, followed by a beep (on SN510, SN710, SN2100
and SN3100 models) once your product is up and running.
For SNi40 and SN6100 models, upon startup, the LEDs light up in the following order:
Power => Run 1
The Power LED lights up first. After a few minutes, the Online LED will light up, followed by a beep
on SN6100 models once your product is up and running.