Objet350 User Guide 6 Operating and Maintaining the Objet350 3DPrinter
DOC-17001 Rev.G 6-67
6. ConnectthecablefromthesensortotheUVmeter.
7. TurnontheUVmeter,andwaituntil“000.0”appearsonthedisplay.
8. Inthewizardscreen,confirmthatthesensorispositionedcorrectly,and
clickNext.
Continuewith"UVMeasurement"below.
UVMeasurement
TheUVlampspowerupandstabilize.(Thistakesseveralminutes.)Then,the
printblockpassesoverthesensorandthewizardcomparesthemeasured
radiationtotherecommendedlevelforeachUVlampandprintingmode.
Duringthisprocess,whichtakes20–40minutes,youneedtomonitorthe
progressasdisplayedinthewizardscreen.
Figure6-99UVmeasurementprogress
Whenusingastand-aloneradiationmeter,resetthemeterandenterthe
reading(measurement)whenyouarepromptedtodoso.
Figure6-100UVMeasurementdialogbox