Studer Innotec SA
next3
30 V 1.3 © Studer-Innotec SA next3 Tech manual
5.2.3.2 battery-side connection
Prepare the batteries for connection: appropriate battery clamps, protection device, cables in good
conditions with correctly fitted clamps.
Fasten the negative cable on to the negative pole (-) of the battery and the positive cable on the
open protection device.
The cable lugs must be carefully fixed and tightened sufficiently to guarantee minimum loss.
Insufficient tightening may cause dangerous heating at the connection point.
During the first start of the unit, it is necessary to check that the parameter values of the
next3 are consistent with the recommendations of the battery manufacturer. Non-
conforming values may be dangerous and/or seriously damage the batteries.
See the chapter about programming and set the proper values at initial commissioning
(with wizard on nx-interface).