Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-23
Note – The table is read in the same way as TABLE 8-3. For examples of logs, see
Appendix B.
TABLE 8-4 Other Logs
Type Description
Size
(Entry Size)
Standard
Storage Period
Archiving Reference Method
Power log Log for recording power events of
the main unit
1920 generations
(M8000/M9000
servers)
720 generations
(M3000/M4000/
M5000 servers)
( x16B )
About 1 month
Archived
showlogs(8)
- XSCF Web
Event log Log for recording system
operations, operator panel
operations, and events reported to
the operating system
4096 generations
( x48B )
About 1 month
Archived
showlogs(8)
- XSCF Web
Console log Log that is recorded as a console
message log if the XSCF console is
specified as the output destination
of the Solaris OS console.
When the input power is turned
off, the log is clear.
512KB /domain,
About 10000
lines/domain
Amount for about 1
week
Archived
showlogs(8)
- XSCF Web
Panic log Console log for a panic occurrence 64KB
(About 1200
lines)
Amount for 1 time
Archived
showlogs(8)
- XSCF Web
IPL log Log for the period from power on
to completion of Solaris OS startup
32KB/domain,
About 600
lines/domain
Amount for 1 time
Archived
showlogs(8)
- XSCF Web
Audit log Log for XSCF audits 4MB About 1 month
Archived
viewaudit(8)
- XSCF Web
Temperature
and humidity
history log
Log containing a history of the
temperature and humidity of the
main unit environment
The humidity history is displayed
only in the high-end server.
16384
generations
(x16B)
(Every 10
minutes)
About 6 months
Archived
showlogs(8)
- XSCF Web