102
step 2 Dismantle the inverter referring to "5 Mechanical Mounting" in reverse steps.
step 3 If necessary, remove the wall-mounting bracket from the wall.
step 4 If the inverter will be reinstalled in the future, please refer to "4.3 Inverter Storage" for a prop-
er conservation.
- - End
9.1.3 Disposal of the Inverter
Users take the responsibility for the disposal of the inverter.
Some parts and devices of the inverter, such as the capacitors, may cause environ-
mental pollution.
Do not dispose of the product together with household waste but in accordance
with the disposal regulations for electronic waste applicable at the installation site.
9.2 Decommissioning the Battery
Decommission the battery in the system after the inverter is decommissioned. Proceed as
follows to decommission a Li-ion battery.
step 1 Disconnect the DC circuit breaker between the battery and the inverter.
step 2 Disconnect the communication cable between the battery and the inverter.
step 3 (Optional) Turn off the switch on LG Chem Li-ion battery or BYD Li-ion battery, if applicable.
step 4 Wait for about 1 minute and then use the multimeter to measure the port voltage of the
battery.
step 5 If the battery port voltage is zero, disconnect the power cables from the battery module.
- - End
SUNGROW is not liable for disposal of the battery.
9 System Decommissioning User Manual