Symbol Explanation
Danger to life due to high voltages!
Only qualified personnel can open and service the inverter.
Do not touch live parts for 10 minutes after disconnection from
the power sources.
Additional grounding point.
2.4 LED Indicator
The LED indicator on the front of the inverter indicates the working state of the inverter.
table 2-1 LED indicator description
LED indicator LED state Definition
Blue
ON
The inverter is running in the on/off-grid mode.
Twinkling
The inverter is at standby or startup state
(without on/off-grid operation).
Red
ON
A system fault has occurred.
Gray
OFF
Both the AC and DC sides are powered down.
2.5 DC Switch
The DC switch is used to safely disconnect the DC circuit whenever necessary.
The inverter operates automatically when input and output requirements are met. Rotate the
DC switch to the “OFF” position to stop the inverter when a fault occurs or when you need to
stop the inverter.
Turn the DC switch to the “ON” position before restarting the inverter.