114
Parameters SH8.0RT SH10RT
SPD DC Type II / AC Type II
Battery input reverse polarity
protection
Yes
Parallel operation on grid port
/ Max. No. of inverters
Master-slave mode / 5 *** (need same inverters type)
System Data
Max. efficiency
98.4 % 98.4 %
European efficiency
97.9 % 97.9 %
Isolation method (solar /
battery)
Transformerless / Transformerless
Degree of protection IP65
Operating ambient tempera-
ture range
-25 - 60
Allowable relative humidity
range (non-condensing)
0 - 100 %
Cooling method Natural convection
Max. operating altitude 4000 m (> 3000 m derating)
Noise (Typical) 30 dB(A)
Display LED
Communication
RS485, WLAN, Ethernet, CAN, 4 × DI, 1 × DO
DC connection type MC4 (PV) / Sunclix (Battery)
AC connection type Plug and play connector
Country of manufacture China
Mechanical Data
Dimensions (W x H x D) 460 mm x 540 mm x 170 mm
Mounting method Wall-mounting bracket
Weight 27 kg
Backup Data
Rated voltage 3 / N / PE, 220 Vac / 230 Vac / 240 Vac
Frequency range 50 Hz / 60 Hz
Total hamonic factor output
voltageLinear load
2%
Switch time to emergency
mode
< 20 ms
Rated output power
8000 W / 8000 VA 10000 W / 10000 VA
11 Appendix User Manual