Website: www.sunsynk.com E-mail: sales@globaltech-china.com
20
Recommended DC Surge Protector
:
Figure 15 – Recommended DC surge protector for the batteries.
In some applications, switching devices may not be required, but overcurrent protectors are still required.
IMPORTANT:
Observe the polarity of the battery terminals on the inverter. If you wire the battery terminals the wrong
way around, you will destroy the inverter and invalidate your warranty.
Before making the final DC connection or closing the DC breaker/ disconnection device, ensure
that the inverter is wired properly. A reverse polarity connection on the battery will damage the
inverter.
Figure 16 - Inverters with appropriate battery connections.