OPERATION & MAINTENANCE MANUAL SWE155F
98
remove all oil to avoid fire.
Do a walk-around inspection on machine: check for
bolt looseness, wire wear out, piping leakage etc. If
any abnormal signs are detected, please clear them.
Check work equipments, cylinder, link, hose free of
crack, wear out or and variation.
Check engine oil level: the level must be between the
lines of “MAX” and “MIN”.
Check coolant level: the coolant level must be
between the lines of “LOW” and “FULL”.
Drain the water and sediment in fuel tank.
Confirmation
Check around the machine to make sure its clear of
person and obstacles.
Adjust weight bearing, height, seat tilting, armrest
angle, backrest angle etc for operators comfort.
Check seat belt and fasten buckle.
Check horn and light to ensure they are properly
functioning.
Check instruments and monitor for any damage.
3.4.5 Engine Start-up
Warning
Do not start the engine, if any signs or marks
are posted to handles in the cab.
Do not start the engine by short-circuiting.
Do not start the machine without operator
seated.
Make sure the surrounding area is clear of
person and obstacles before starting the engine.
Sound the horn to warn people.
Do not start the machine in a confined area.
Exhaust gas is toxic, when starting the engine in
a confined area, be careful to ensure good
ventilation.
Note