OPERATION & MAINTENANCE MANUAL SWE155F
113
3.4.14 Emergency Stop for Boom
If the engine fails to start due to unexpected
shutdown, it’s necessary to lower the boom and
keep bucket down to ground to prevent
accidents arising from boom falling off as well
as to facilitate service.
Carry out the following operation in 5 minutes
if expected engine stop happens.
Set pilot control lever to ON position.
Honk the horn to alert.
Gradually move right control lever (for boom
action controlling) forward.
Note
Do not operate too quickly, failure to do
so may cause boom sudden up
movement and lead to accidents.
Do not operate any other lever and
actions, failure to do so; boom can not be
lowered due to pressure depletion in
accumulator.
3.4.15 Parking Machine
1 Drive machine to parking area. The area must
be firm level ground.
2 Release all operate levers and keep them in
NEUTRAL position.
3 Set pilot safety lever to LOCK position.
4 Turn throttle knob anticlockwise to MIN,
allow engine to idle at low speed for 5
minutes.
5 Set starting key to OFF position, remove the
key.
6 Close all doors, windows. Shut access door,
tool box, engine cover and fuel tank.

Table of Contents