EasyManua.ls Logo

SUNWARD SWE155F - Cooling System; Air Conditioning System; Other

SUNWARD SWE155F
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION & MAINTENANCE MANUAL SWE155F
132
4.4.7 Cooling System
Item
Qty.
Interval (hours)
8
50
100
250
500
1000
2000
Check coolant level
1
Check and adjust fan belt
tension
1
Replace coolant
2328L
Clean up
radiator and
hydraulic oil
cooler core
Outside
1
Inside
1
When replacing coolant
Note:※ If the machine is used at dusty area, shorten maintenance interval.
4.4.8 Air Conditioning System
Part
Qty.
Interval (hours)
8
50
100
250
500
1000
2000
Clean A/C condenser
1
△※
Change A/C
filter element
Outer
1
Inner
1
Note:※ If the machine is used at dusty area, shorten maintenance interval.
4.4.9 Other
Part
Qty.
Interval (hours)
8
50
100
250
500
1000
2000
Check bucket teeth for wear
and looseness
——
Change bucket
1
When necessary
Adjust bucket connection
clearance
1
When necessary
Check and change seat belt
1
Every three yearsReplace
Add windshield detergent
——
When necessary
Check track for slack
2
Adjust track tension
2
When necessary
Check air conditioning
system
1
Wash cab floor mat
1
When necessary

Table of Contents