Lower the bottom surface of the bucket on a block,
check that the work equipment is in a stable condition,
then set pilot safety lever to the LOCK position.
Place a metal rod (diameter is a little smaller than pin)
against the back of the pin), use hammer to knock out
pin (1), then remove bucket teeth (2).
Clean mounting surface, place new bucket teeth (2) to
teeth holder, push pin (1) partly into it by hand, then
use hammer to knock in lock pin to position it to
bucket holder.
4.5.4 Every 50 Hours Maintenance
Carry out the following maintenance operation
every 50 hours.
4.5.4.1 Checking and Adjusting Track Tension
For details, please refer to chapter 4.5.3.4.
4.5.4.2 Draining Water and Sediment from Water Separator
For details, please refer to chapter 4.5.2.2.
4.5.5 Every 100 Hours Maintenance
When the machine works for every 500 hours, take the
maintenance as specified in this chapter and carry out
maintenance of every 50 hours at the same time.
4.5.5.1 Checking and Adjusting Fan Belt Tension
For details, please refer to chapter 4.5.2.7.