OPERATION & MAINTENANCE MANUAL SWE155F
7
hydraulic system.
Do not allow water or vapor to reach electrical
equipment.
Do not disassemble components such as engine pump
controller, sensor etc.
(6) Wiper Label
Use the wiper properly.
(7) Filter Element Maintenance Safety Label
Replace pilot oil filter ……every 400 hours
Stop machine on firm level ground.
Lower bucket to the ground.
Run engine at low-speed for 5 minutes.
Shut down the engine, remove the key.
Release inner pressure in the hydraulic system by
operating left and right pilot handles.
Set pilot control lever in LOCK (UP) position.
Use wrench for filter to remove filter housing off the
filter head cover by rotating counterclockwise.
Remove filter core and used O-ring.
Clean the area in contact by head cover and O-ring.
Apply a new layer of fresh hydraulic oil, and place it
in position.
Lubricate new filter core with a thin layer of clean
hydraulic oil on the ring section. Push filter core
upward while moving it forward and backward
alternately to install it.
Clean filter housing.