6-2 ELECTRICAL SYSTEM
CAUTIONS IN SERVICING
CONNECTORS
• When disconnecting a connector, be sure to hold the termi-
nals; do not pull the lead wires.
• When connecting a connector, push it in so it is firmly attached.
• Inspect the connector for corrosion, contamination and any
breakage in the cover.
CLAMPS
• Refer to “WIRE ROUTING” (!7-8) for proper clamping pro-
cedures.
• Bend the clamp properly, as shown in the illustration.
• When clamping the wire harness, do not allow it to hang down.
• Do not use wire or any other substitute for the band-type clamp.
WIRING PROCEDURE
• Properly route the wire harness according to “WIRE ROUT-
ING”. (!7-8)
USING THE MULTI CIRCUIT TESTER
• Properly use the multi circuit tester (+) and (-) probes. Im-
proper use can cause damage to the vehicle and tester.
• If the voltage and current values are not known, begin measur-
ing in the highest range.
• When measuring the resistance, make sure that no voltage is
applied. If voltage is applied, the tester will be damaged.
• After using the tester, turn the switch to the OFF position.
"
Before using the multi circuit tester, read its instruction
manual.