5-28 PAIR (AIR SUPPLY) SYSTEM
PAIR (AIR SUPPLY) SYSTEM INSPECTION
HOSES
Inspect the hoses for wear or damage.
Inspect that the hoses and pipes are securely connected.
PAIR CONTROL VALVE
Inspect that air flows through the PAIR control valve air inlet
port to the air outlet ports.
If air does not flow out, replace the PAIR valve with a new one.
Connect the vacuum pump gauge to he vacuum port of the
control valve as shown in the photograph.
Apply negative pressure of the specification slowly to the con-
trol valve and inspect the air flow.
If air does not flow out, the control valve is in normal condition.
If the control valve does not function within the specification,
replace the control valve with a new one.
& Negative pressure range: More than 72 kPa
(540 mmHg)
$ 09917-47010: Vacuum pump gauge
#
Use a hand operated vacuum pump to prevent the con-
trol valve damage.
PAIR REED VAVLE
Remove the PAIR valve cover.
Inspect the reed valve for the carbon deposit.
If the carbon deposit is found in the reed valve, replace the
PAIR control valve with a new one.