VL800K5 (’05-MODEL) 14-43
MALFUNCTION CODE AND DEFECTIVE CONDITION
DTC No.
DETECTED
ITEM
DETECTED FAILURE CONDITION CHECK FOR
C00 NO FAULT
––––––––––– –––––––––––
C12
CKP sensor The signal does not reach ECM for 3
sec. or more, after receiving the starter
signal.
CKP sensor wiring and mechan-
ical parts.
(CKP sensor, lead wire/coupler
connection)
P0335
C13/C17
IAP sensor The sensor should produce following
voltage.
0.1 V sensor voltage < 4.8 V
In other than the above range, C13
(P1750) or C17 (P0105) is indicated.
IAP se sor, lead wire/coupler
connec ion.
P1750/P0105
C14
TP sensor The sensor should produce follow ng
voltage.
0.1 V sensor voltage < 4.8 V
In other than the above range, C14
(P0120) is indicated.
TP sensor, lead wire/coupler
connection.
P0120
H
Sensor voltage is higher than specified
value.
TP sensor circuit shorted to
VCC or ground circuit open.
L
Sensor voltage is lower than specified
value.
TP sensor circuit open or
shorted to ground or VCC circuit
open.
C15
ECT sensor The sensor voltage should be the fol-
lowing.
0.1 V sensor voltage < 4.6 V
In other than the above range, C15
(P0115) is indicated.
ECT sensor, lead wire/coupler
connection.
P0115
H
Sensor voltage is higher than specified
value.
ECT sensor circuit open or
ground circuit open.
L
Sensor voltage is lower than specified
value.
ECT sensor circuit shorted to
ground.