10-6 EMISSION CONTOROL INFORMATION
Blocked tube
B
Plug the canister port B.
Air should not flow through the carburetor surge control valve
and out the open air port.
Replace the carburetor surge control valve if air leaks out the
open air port.
Air
B
A
Remove the vacuum pump and blow air through the air vent
port A.
Air should flow through the carburetor surge control valve and
out the canister port B.
Replace the carbretor surge control valve if air does not flow
out the canister port B.