DNX-11 Installation Proper Grounding
DOC-001-11001 (Rev. 006) 10 DNX Quick Install & Setup Guide
Grounding via Grounding Strap
Using two #10-32 screws and external-toothed lockwashers (provided), connect a grounding
strap lug to the grounding points near the power terminal block as shown in Figure 8.
Figure 8: Grounding Strap Connection.
++
++--
--
++--
++--
TALK BATTERY
TALK BATTERY
SIGNAL BATTERY
SIGNAL BATTERY
DC POWER SLOT #2
DC POWER SLOT #1
AC POWER SLOT #2
AC POWER SLOT #1
#10-32
Screws
External-Toothed
Lockwashers
Grounding Strap