Chapter 2 TL1 Command Syntax and Description
Retrieve Equipment (RTRV-EQPT)
102 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Normal Retrieve Response
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
"<aid>:<keyword>,<value>"<cr><lf>
;
Example
To display the current baud rate setting for the local serial communications (COML)
port:
Input
RTRV-EQPT::COML:TP1000::BAUD;
Response Example
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"COML:BAUD,9600"
;
Autonomous Message
None
<aid>
cont’d
NTP Equipment settings for the NTP:
Peer Server
Authentication
Note: See ED-EQPT for NTP Parameters, on page 51 for
<keywords> and descriptions of their possible <values>.
Table 2-18. RTRV-EQPT Output Field
Field Description
<aid> The access identifier for the equipment component (refer to Edit
Equipment (ED-EQPT), on page 45 for valid <aid>).
<keyword> The specific equipment parameter being requested (refer to Edit
Equipment (ED-EQPT), on page 45 for valid <keyword>).
<value> The current setting of the requested equipment parameter
Parameter Value Description