097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 131
Chapter 2 TL1 Command Syntax and Description
Set Attribute (SET-ATTR)
Set Attribute (SET-ATTR)
This command sets the alarm level that an event generates. Use this command also
to reset all alarm levels to factory settings, and to specify whether or not the system
escalates alarms.
This command has a default access level of ADMIN.
Syntax
SET-ATTR:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];
Parameter Value
Description
See
Table 2-32
for <keyword> and <value> descriptions.
<aid> SYS The command’s effect is at the system level.
IMC Sets the alarm level for the specified Information Management
Card module alarm to the specified value.
IOCm Sets the alarm level for the specified alarm in the specified
Input/Output Card module to the specified value.
m = “1” for the slot marked “IOC 1" on the main shelf
m = “2” for the slot marked “IOC 2" on the main shelf
GPS Sets the alarm level for the GPS alarm to the specified value.
PRS Sets the alarm level for the PRS alarm to the specified value.
OUTg Sets the alarm level on the Output group specified by g:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
INPp Sets the alarm level for the alarm related to the specified input
port to the specified value.
p = “1” for the input marked INP 1 on the Input Connector
module
p = “2” for the input marked INP 2 on the Input Connector
module
RTMg Sets the alarm level on the Retimer group specified by g:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
E422g Sets the alarm level on the EIA-422 output group specified by g:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf

Table of Contents

Other manuals for Symmetricom TimeProvider 1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1100 and is the answer not in the manual?

Symmetricom TimeProvider 1100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1100
CategoryClock
LanguageEnglish

Related product manuals