097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 73
Chapter 2 TL1 Command Syntax and Description
Retrieve Alarm Condition (RTRV-ALM)
Retrieve Alarm Condition (RTRV-ALM)
This command retrieves information on currently active alarms.
This command has a default access level of USER.
Syntax
RTRV-ALM:[<tid>]:[<aid>]:[<ctag>];
Parameter Value Description
<aid> ALL
(or null)
Retrieves information for all alarms that are currently active
in the entire system.
SYS Retrieves information for all currently active system-level
alarms.
IMC Retrieves information for all currently active alarms from the
Information Management Card module.
IOCm Retrieves information for all currently active alarms from the
Input/Output Card module specified by m.
m = “1” for the slot marked “IOC 1" on the main shelf
m = “2” for the slot marked “IOC 2" on the main shelf
GPS Retrieves information for all currently active alarms from the
GPS module.
PRS Retrieves information for all currently active alarms from the
PRS module.
INPp Retrieves information for all currently active alarms from the
specified input port.
p = “1” for the input marked INP 1 on the Input Connector
module
p = “2” for the input marked INP 2 on the Input Connector
module
RTMg[-p] Retrieves information for all currently active alarms from the
specified Retimer module [and port].
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
p = “1” for Port 1 on the Retimer module
p = “2” for Port 2 on the Retimer module