Chapter 2 TL1 Command Syntax and Description
Remove Equipment (RMV-EQPT)
72 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Example
To clear the OUTBEQPT alarm after permanently removing the Output module from
group B:
Input
RMV-EQPT::SYS:TP1000::OUTB;
Response Example
TP-SSU
05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
None
SYS
(cont’d)
RTMg Clears currently active RTMgEQPT alarms from the Retimer
module specified by g, if the module is not to be replaced:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
EXPN Clears currently active EXPNEQPT alarms if the panel is not
to be replaced.
TPIU Clears currently active TPIUEQPT alarms if the TPIU is not
to be replaced.
<aid> <keyword> Description