097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 45
Chapter 2 TL1 Command Syntax and Description
Edit Equipment (ED-EQPT)
Edit Equipment (ED-EQPT)
This command is used to provision equipment parameters. To provision NTP
parameters, see ED-EQPT for NTP Parameters, on page 51.
This command has a default access level of ADMIN.
Syntax
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];
Parameter Value
Description
See
Table 2-5
for <keyword> and <value> descriptions.
<aid> SYS The command’s effect is at the system level.
COMp The command’s effect is on the communication port
specified by p:
p = “L” for the local serial port
p = “R” for the remote serial port
p = “I” for the IP (Ethernet) port
IOCm The command’s effect is on the IOC module specified by m:
m = “1” for the slot marked “IOC 1" on the main shelf
m = “2” for the slot marked “IOC 2" on the main shelf
GPS The command’s effect is on the GPS input.
PRS The command’s effect is on the PRS input.
INPp The command’s effect is on the input port specified by p:
p = “1” for the input marked INP 1 on the Input Connector
module
p = “2” for the input marked INP 2 on the Input Connector
module
OUTg The command’s effect is on the output group specified by g:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
RTMg[-p] The command’s effect is on the Retimer group and port
specified by g[-p]:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
p = “1” for Port 1 on the Retimer module
p = “2” for Port 2 on the Retimer module

Table of Contents

Other manuals for Symmetricom TimeProvider 1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1100 and is the answer not in the manual?

Symmetricom TimeProvider 1100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1100
CategoryClock
LanguageEnglish

Related product manuals