097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 127
Chapter 2 TL1 Command Syntax and Description
Retrieve Threshold (RTRV-TH)
Example
To retrieve the value set for the performance threshold:
Input
RTRV-TH::PRS:TP1000;
Response Example
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"MTIE-1,750,OK"
"MTIE-5,750,OK"
"MTIE-10,1000,OK"
"MTIE-50,2000,OK"
"MTIE-100,2000,OK"
"MTIE-500,2000,OK"
"FFOFF-60,2700,OK"
"INPFRQ,2000,OK"
"SLIPCHG,25,OK"
;
Autonomous Message
None
Table 2-30. RTRV-TH – Output Fields
Field Value Description
<aid> The aid associated with the PM ID
<alarm threshold> MTIE-### = 1 – 100000
FFOFF-60 = 1 – 10000000
SLIPCHG = 0 – 60
Performance threshold that generates an alarm,
see Table 2-32
<pm status> OK | ALM PM measurement status.
OK = measurement within range
ALM = measurement is over threshold