Chapter 2 TL1 Command Syntax and Description
Delete Performance Monitoring Data (DLT-PM-DATA)
38 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Delete Performance Monitoring Data (DLT-PM-DATA)
This command deletes the current set of performance monitoring data for one input
channel. All Performance Data associated with the specified input is erased.
This command has a default access level of USER.
Syntax
DLT-PM-DATA:[<tid>]:[<aid>]:[<ctag>];
Example
To delete all performance data associated with the specified module:
Input
DLT-PM-DATA:::TP1000;
Normal Response
TP-SSU
05-02-10 13:35:56
M TP1000 COMPLD
;
aid Description
IOC[m]-GPS GPS input on either of the two IOC modules (m = 1 or 2).
IOC[m]-PRS PRS input on either of the two IOC modules (m = 1 or 2).
IOC[m]-INP[p] Input 1 or Input 2 on either of the two IOC modules
(m = 1 or 2 and p = 1 or 2).