EasyManuals Logo

Symmetricom TimeProvider 1100 Reference Guide

Symmetricom TimeProvider 1100
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Chapter 2 TL1 Command Syntax and Description
Retrieve Sync (RTRV-SYNC)
124 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Normal Retrieve Response
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
"<aid>:<keyword>,<value>"<cr><lf>
;
Example
To retrieve the current priority setting for input reference 2:
Input
RTRV-SYNC::INP2:TP1000::PRIORITY;
Response Example
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"INP2:PRIORITY,3"
;
Autonomous Message
None
Table 2-29. RTRV-SYNC Output Field
Field Description
<aid> The access identifier for the equipment component (Refer to Edit Sync
(ED-SYNC), on page 55 for valid <aid>)
<keyword> The specific equipment parameter being requested (Refer to Edit Sync
(ED-SYNC), on page 55 for valid <keyword>)
<value> The current setting of the requested equipment parameter

Table of Contents