Appendix C Events
168 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
HOLDFLT Defines if the Retimer
mode operates or not
when the LO enters
Holdover mode of
operation. The output
groups are provisioned
for fault strategies.
T1 CUTTHRU
RETIMER – In fault mode the
output signals are retimed
CUTTHRU – In fault mode the
cut-thru mode is enabled, and
output signals are not retimed.
RTMLBO The Line Buildout on the
specified Retimer port
has changed.
T1 0
0 = 0 to 133 ft
1 = 133 to 266 ft
2 = 266 to 399 ft
3 = 399 to 533 ft
4 = 533 to 650 ft
RTMSTATE The state of the specified
Retimer port has
changed.
T1 ENABLE
ENABLE – Enable the Retimer
port
DISABLE – Disable the
Retimer port and clear all
alarms associated with the
port.
SLIPCHG The Retimer slip
threshold has changed.
T1 4 1 to 255
SLIPCLR The Retimer slip counter
has been cleared
T1 NA NA
Table C-2. Event Code Condition Descriptions
Event ID
Event Condition Description
IMC Event Conditions
ACCLVL USER ACCESS LEVEL HAS CHANGED
ACO AUDIO ALARM IS DEACTIVATED
ALMCHG ALARM PARAMETER HAS CHANGED, <keyword>,<alarm>
AOMERGE AUTONOMOUS EVENT REPORTING HAS CHANGED, <state>
BAUD SERIAL BAUDRATE HAS CHANGED, <value>
CMDCHG COMMAND ACCESS LEVEL HAS CHANGED, <command>
ECHO SERIAL PORT ECHO MODE HAS CHANGED, <state>
FEATURE SYSTEM FEATURE HAS BEEN ACTIVATED, <feature>
Table C-1. Event Identifiers (Continued)
Event ID
or
CONDTYPE
Event Description
AID
TYPE
Default Value Value Description