097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 75
Chapter 2 TL1 Command Syntax and Description
Retrieve Alarm Condition (RTRV-ALM)
Example
To display all currently active alarms from the system:
Input
RTRV-ALM::ALL:TP1000;
Response Example
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"SYS,EQPT:MJ,EXPFAIL,SA,05-02-10,13-37-39,,:\"EXPANSION CONNECTIVITY FAILED\""
"IOC1,EQPT:MJ,CLKHOLD,SA,05-02-10,13-37-39,,:\"CLOCK ENTERED HOLDOVER MODE\""
"IOC2,EQPT:MJ,CLKHOLD,SA,05-02-10,13-37-39,,:\"CLOCK ENTERED HOLDOVER MODE\""
;
Autonomous Message
None