ALGORITHMS
M5DYN
Rev 1.1 Page 12
under UTIL before setting this control.
However, if the red overload LED
flashes, turn down INLEV a couple of
dBs. The control does not affect the
bypassed signal level. Normally, you do
not have to change the factory default
setting.
OUTLEV OFF - 0.0 dB. Sets the output level of the reverb in 0.5
dB steps. The function of this control is
to maximize dynamic range by allowing
the reverb algorithm to output maximum
signal to the DA converters. It affects the
output PPM reading. There is a separate
output level control for adjusting the
analog output level in UTIL. Set the
analog input (if you use analog input)
and the INLEV adjustments before
setting OUTLEV. The control does not
affect the bypassed signal level.
Normally, you do not have to change the
factory default setting.
DECAY 0.3 - 3.0 Sec. Reverberation decay time.
x LOW 0.01 - 2.5 times Relative decay time multiplier for low
frequencies.
x HIGH 0.01 - 2.0 times Multiplier for the high frequencies. If
x HIGH time is set to 0.5, the HI decay
time is half that of the nominal DECAY
setting.
INITLEV off - 0.0 dB. Sets the level of the initial pattern. The
purpose of this control is to balance the
initial (early) reflection levels against the
reverberating part of the reverb
algorithm.
REVLEV off - 0.0 dB. Sets the level of the reflection envelope
relative to the early reflections in 0.5 dB
steps. If REVLEV is set to
off
you will
hear only the initial reflections.
LM-XOVR 20 Hz - flat Sets the crossover frequency for the
x LOW decay time multiplier in 1/3-
octave steps.