• If necessary, replace the cable 0WCU1419xx.
6.15 EQUIPMENT TESTING AFTER THE
INTERVENTION OF TECHNICAL SERVICE
After a technical service intervention, the technician MUST check - in the same conditions in which
the customer discovered the problem - that the fault has been resolved.
The technician MUST also perform the following standard operating tests:
TEST 1: with the equipment on, perform an exercise (QUICK START) and check that the equip-
ment gradient and speed vary as the position of the joystick changes. [ Range: gradient: minimum
- average - maximum; speed: minimum - average - maximum].
TEST 2: Check that the peripheral devices function correctly.
TEST 3: Check the integrity of cables and that there aren’t any trapped cables. If there’s a stripped
cable (also only with damaged outer sheath), replace cables and arrange them correctly so that
the cables are not trapped.
TEST 4: Check the cables arrangement along the machine. If necessary arrange them correctly.
It’s also necessary to perform the following checks:
• Check the presence / the state of wear of warning labels. Check if the warning labels are
readable;
• If the equipment must be xed to wall / ground / ceiling or together with other machines:
check that the equipment is actually xed.
6.16 WHAT TO DO IN CASE OF EQUIPMENT OUT OF
ORDER / BLOCKED
WARNING: In the case of an out of order machine and a blocked machine, the plug must
be removed from the mains socket.
6.17 MESSAGE ON THE DISPLAY: ‘PRESS “YES” TO
QUIT THIS MESSAGE AND START TRAINING’
In the case of error 16 or 17, the following message appears on the display: “Press YES to
quit this message and start training”.
Click the YES button on the display to try to make the error disappear.
Only if the error persists or if the machine does not work correctly, see the troubleshooting proce-
dure detailed in the paragraph: $”6.4 DRIVE ERROR CODE LIST”.
TECHNOGYM RUN Technical Service Guide
Rev. 1.0
- 94 - TSG-00284-EN- Uncontrolled copy if printed