6.3 PARAMETERS (STIWI DRIVE)
ID (Par.) VALUES DESCRIPTION
P01 8 Default linear speed
P02 100 Default acceleration and deceleration
P03 0 Default inclination setpoint
P04 7 Proportional gain PID
P05 150 Integral gain PID
P06 0 Linear or S-shaped ramp
P07 0 Flag that signals the intervention of the DC motor encod-
er alarm
P08 25 Serial communication watchdog
P09 15 DC encoder error timeout
P10 0 Flag that signals the reception of the SW emergency but
not the reception of the HW emergency
P11 91 Roller diameter
P12 208 Pulley ratio
P13 0 Flag that signals the intervention of the AC motor encod-
er alarm
Tab. 19
6.4 DRIVE ERROR CODE LIST
When an error occurs, rst upgrade the Low Kit FW to the latest released version.
ER-
ROR
CODE
ERROR DESCRIPTION SOLUTION
01 OVER-TEMPERATURE: the temperature
of one of the two drive heat-sinks (inverter
part and Pfc part) exceeds the maximum
permitted temperature threshold for at
least 3 sec.
- Check for dust in the drive components.
If necessary, clean the drive.
- If it is always present even when the
equipment has just been turned on, with
the electronics cold, replace the drive
(Low Kit).
TECHNOGYM RUN Technical Service Guide
Rev. 1.0
- 69 -TSG-00284-EN- Uncontrolled copy if printed